York Yp9c C User Manual

538513- YTG-A-0809  
DESCRIPTION  
These compact units employ induced combustion, reliable hot  
surface ignition and high heat transfer aluminized tubular heat  
exchangers. The units are factory shipped for installation in  
upflow or horizontal applications and may be converted for  
downflow applications.  
These furnaces are designed for residential installation in a  
basement, closet, alcove, attic, recreation room or garage and  
are also ideal for commercial applications. All units are factory  
assembled, wired and tested to assure safe dependable and  
economical installation and operation.  
TECHNICAL GUIDE  
UP TO 98%  
MODULATING (ECM MOTOR)  
GAS-FIRED RESIDENTIAL  
MULTI-POSITION GAS FURNACES  
These units are Category IV listed and may be vented either  
through side wall or roof applications using approved plastic  
combustion air and vent piping.  
MODELS: YP9C*C  
NATURAL GAS  
FEATURES  
Modulating heating operation includes:  
60 - 120 MBH INPUT  
- Modulating gas valve, inducer and circulating blower  
- Modulating operation from 100% to 35% input in 100  
increments with nearly constant temperature rise.  
Easily applied in upflow, horizontal left or right, or downflow  
installation with minimal conversion necessary.  
Compact, easy to install, ideal height 33" tall cabinet.  
ECM variable speed drive for cooling SEER enhancement,  
improved comfort with optional airflow delay profiles, and  
continuous fan options for IAQ performance.  
Easy access to controls to connect power/control wiring.  
Built-in, high level self diagnostics with fault code display.  
Low unit amp requirement for easy replacement application.  
All models are convertable to use propane (LP) gas.  
Electronic Hot Surface Ignition saves fuel cost with  
increased dependability and reliability.  
100% shut off main gas valve for extra safety.  
24V, 40 VA control transformer and blower relay supplied for  
add-on cooling.  
Airflow leakage less than 1% of nominal airflow for  
ductblaster conditions.  
EFFICIENCY  
RATING  
CERTIFIED  
Solid removable bottom panel allows easy conversion.  
Hi-tech tubular aluminized steel primary heat exchanger with  
stainless steel tube/aluminum fin secondary heat exchanger  
for outstanding efficiency.  
When paired with a  
York heat pump  
No knockouts to deal with, making installation easier.  
Movable duct connector flanges for application flexibility.  
Quiet inducer operation, burner, and blower operation.  
Inducer rotates for easy conversion of venting options.  
Due to continuous product improvement,  
specifications are subject to change without notice.  
up-to-date technical information.  
Fully supported blower assembly for easy access and  
removal of blower.  
External air filters used for maximum flexibility in meeting  
customers IAQ needs.  
Additional rating information can be found at  
Insulated blower compartment for thermal and acoustic  
performance.  
WARRANTY  
1/4 turn knobs provided for easy independent door removal.  
Lifetime limited warranty on both heat exchangers to the original pur-  
chaser; a 20-year limited warranty from original installation date to  
subsequent purchaser.  
Internal condensate trap design (patent pending) provides  
condensate management options, easy visual operation  
check, and is self priming to prevent nuisance problems.  
10-year warranty on the heat exchanger in commercial applications.  
Standard 5-year limited Parts warranty.  
These models may be connected as part of a communicating  
control system using a 4-wire connection bus.  
Extended 10-year limited parts warranty when product is regis-  
tered online within 90 days of purchase for replacement or clos-  
ing for new home construction.  
The York YP9C modulating ECM furnace is part of a “Hybrid  
Comfort System” when paired with a York Heat Pump.  
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE  
538513- YTG-A-0809  
Sidewall Vent Termination Kit -  
FILTER PERFORMANCE  
The airflow capacity data published in the “Blower Perfor-  
mance” table represents blower performance WITHOUT filters.  
S1-1HT0901 (3")  
S1-1HT0902 (2")  
All applications of these furnaces require the use of field  
installed air filters. All filter media and mounting hardware or  
provisions must be field installed external to the furnace cabi-  
net. DO NOT attempt to install any filters inside the furnace.  
For use on sidewall, two-pipe installations only. Provide a more  
attractive termination for locations where the terminal is visable  
on the side of the home.  
Condensate Neutralizer Kit -  
NOTE: Single side return above 1800 CFM is approved as long  
as the filter velocity does not exceed filter manufacturer’s rec-  
ommendation and a transition is used to allow use of a 20 x 25  
filter.  
1NK0301  
Neutralizer cartridge has a 1/2" plastic tube fittings for installa-  
tion in the drain line. Calcium carbonate refill media is also  
available from the Source 1 Parts (p/n 026-30228-000).  
Recommended Filter Sizes  
Side Return Filter Racks -  
Cabinet  
Size  
Side  
(in)  
Bottom  
(in)  
CFM  
1SR0200 - All Models  
1SR0402 - All Models  
1SF0101 - All Models  
1200  
1600  
2000  
2000  
B
C
C
D
16 x 25  
16 x 25  
16 x 25  
20 x 25  
20 x 25  
22 x 25  
(2) 16 x 25  
(2) 16 x 25  
Bottom Return Filter Racks -  
1BR0517 or 1BR0617 - For 17-1/2” cabinets  
1BR0521 or 1BR0621 - For 21” cabinets  
1BR0524 or 1BR0624 - For 24-1/2” cabinets  
NOTES:  
1. Air velocity through throwaway type filters may not exceed 300 feet per min-  
ute (91.4 m/min). All velocities over this require the use of high velocity fil-  
ters.  
1BR05xx series are galvanized steel filter racks. 1BR06xx are  
pre-painted steel filter racks to match the appearance of the fur-  
nace cabinet.  
2. Do not exceed 1800 CFM using a single side return and a 16x25 filter. For  
CFM greater than 1800, you may use two side returns or one side and the  
bottom or one return with a transition to allow use of a 20x25 filter.  
Combustible Floor Base Kit -  
Unit Clearances to Combustibles  
For installation of these furnaces in downflow applications  
directly onto combustible flooring material, These kits are  
required to prevent potential overheating situations. These kits  
are also required in any applications where the furnace in  
installed in a downflow configuration without an evaporator coil,  
where the combustible floor base kit provides access for com-  
bustible airflow.  
Upflow  
Downflow  
Horizontal  
Application  
Top  
1"  
0"  
0"  
0"  
0"  
0"  
0"  
0"  
0"  
0"  
0"  
0"  
0"  
1"  
0"  
Vent  
Rear  
Side  
Front1  
1CB0517 - For 17-1/2” cabinets  
1CB0521 - For 21” cabinets  
1CB0524 - For 24-1/2” cabinets  
Combustible2  
Floor  
Combustible  
Combustible  
Yes  
Closet  
Yes  
No  
Yes  
No  
Line Contact  
Yes  
EAC Transition Kits -  
1. Line contact only permitted between lines formed by the intersection of the  
rear panel and side panel (top in horizontal position) of the furnace jacket  
and building joists, studs or framing.  
2. For combustible floors only when used with special sub-base.  
All furnaces approved for alcove and attic installation.  
For installation of EAC accessories with these furnaces to pro-  
vide easy transition of return airflow through the EAC to get the  
proper sealing and reduced airflow leakage.  
1TK1001 - For all models using side return  
1TK1017 - For 17-1/2” cabinets using bottom return  
1TK1021 - For 21” cabinets using bottom return  
1TK1024 - For 24-1/2” cabinets using bottom return  
ACCESSORIES  
Propane (LP) Conversion Kit -  
1NP0681 - All Models  
High Altitude - No high altitude kits are required.  
This accessory conversion kit may be used to convert natural  
gas (N) units for propane (LP) operation.  
Thermostats - Compatible thermostat controls are available  
through accessory sourcing. For optimum performance and  
installation, refer to the UPGNET “Low Voltage Wiring Diagram”  
document to select and apply controls.  
Do not use Conversion Kit S1-1NP0680 with these models, as  
the control/gas valve combination have been updated, and that  
kit S1-1NP0680 will not function correctly with these models.  
Concentric Vent Termination -  
S1-1CT0302 (2")  
S1-1CT0303 (3")  
For use through rooftop, sidewall. Allows combustion air to  
enter and exhaust to exit through single common hole. Elimi-  
nates unslightly elbows for a cleaner installation.  
Johnson Controls Unitary Products  
3
Blower Performance CFM - Any Position  
060B12*C  
High / Low Speed Cooling CFM  
080B12*C  
Jumper Settings  
Hi Cool  
1305  
1100  
1065  
1000  
960  
Lo Cool  
850  
715  
690  
650  
625  
495  
585  
430  
450  
400  
400  
400  
Hi Cool  
1290  
1090  
1015  
1000  
960  
Lo Cool  
840  
710  
660  
650  
625  
495  
585  
430  
445  
400  
400  
400  
COOL Jumper  
ADJ Jumper  
H
MH  
H
B
B
A
A
C
B
C
B
A
A
C
C
MH  
H
760  
760  
ML  
MH  
L
900  
900  
660  
660  
690  
680  
ML  
L
600  
600  
620  
620  
ML  
L
550  
540  
High / Low Speed Cooling CFM  
100C16*C  
080C16*C  
Jumper Settings  
Hi Cool  
1670  
1295  
1385  
1175  
1245  
995  
Lo Cool  
1085  
840  
Hi Cool  
1655  
1275  
1345  
1160  
1210  
1000  
1045  
955  
Lo Cool  
1075  
820  
COOL Jumper  
ADJ Jumper  
H
MH  
H
B
B
A
A
C
B
C
B
A
A
C
C
900  
875  
765  
755  
MH  
H
810  
785  
645  
650  
ML  
MH  
L
1055  
935  
685  
680  
605  
620  
905  
590  
910  
590  
ML  
L
850  
550  
870  
565  
815  
530  
815  
530  
ML  
L
765  
500  
785  
510  
High / Low Speed Cooling CFM  
120D20*C  
100C20*C  
Jumper Settings  
Hi Cool  
2215  
1765  
1820  
1605  
1635  
1270  
1445  
1055  
1155  
960  
Lo Cool  
1440  
1145  
1180  
1040  
1060  
825  
Hi Cool  
2180  
1760  
1800  
1595  
1620  
1255  
1435  
1050  
1160  
960  
Lo Cool  
1415  
1140  
1170  
1035  
1050  
815  
COOL Jumper  
ADJ Jumper  
H
MH  
H
B
B
A
A
C
B
C
B
A
A
C
C
MH  
H
ML  
MH  
L
940  
935  
685  
680  
750  
755  
ML  
L
620  
615  
1040  
860  
675  
1035  
840  
670  
ML  
L
560  
545  
All CFM’s are shown at 0.5” w.c. external static pressure.These units have variable speed motors that automatically adjust to provide constant CFM from 0.0”  
to 0.6” w.c. static pressure. From 0.6” to 1.0” static pressure, CFM is reduced by 2% per 0.1” increase in static. Operation on duct systems with greater than  
1.0” w.c. external static pressure is not recommended.  
NOTE: At some settings, LOW COOL airflow may be lower that what is required to operate an airflow switch on certain models of electronic air cleaners. Con-  
sult the instructions for the electronic air cleaner for further details.  
Subject to change without notice. Published in U.S.A.  
538513- YTG-A-0809  
Copyright © 2009 by Johnson Controls, Inc. All rights reserved.  
Supersedes: 410821-YTG-C-0409  
Johnson Controls Unitary Products  
5005 York Drive  
Norman, OK 73069  

Lexmark P 6250 User Manual
Metrologic Instruments Voyagergs Ms9590 User Manual
Panasonic Cs C28cku User Manual
Panasonic Cs W9dkr User Manual
Panasonic Cu E21fkr User Manual
Philips M2922a User Manual
Philips M2926a User Manual
Samsung Aw1805b User Manual
Tripp Lite Apsx2424 User Manual
Xerox Workcentre M20 User Manual